Our projects

Real installations from our customers' homes: case studies from Bushey and Hertfordshire with their real figures, and heating and plumbing projects across London.

A Vaillant aroTHERM plus heat pump installed on a base in a back garden
A Vaillant aroTHERM plus, from one of our installs

Case study · Bushey

A maximum flow temperature of 40°C, where the original design allowed 45°C

A 12 kW Vaillant aroTHERM plus heat pump we installed in Bushey, Hertfordshire. The lower the flow temperature, the less hard a heat pump has to work.

10.8kWHeat loss at -2.3°C, the design outside temperature
45°CFlow temperature the original design allowed
40°COur maximum flow temperature, weather compensated
over4.0SCOP so far: units of heat for each unit of electricity, with updates to follow

Figures so far, with updates to follow.

“Our installer has assured and reassured us that he will provide remote and in person support to ensure that we achieve a comfortable temperature throughout our home.”

Nicole, homeowner, on Visit a Heat Pump
Underfloor heating circuits laid in loops across the floor of a house extension
Underfloor heating going down in the extension

Case study · Hertfordshire

One 32 kW boiler, where previous quotes suggested another boiler to reach 65 kW

A full renovation of a 5 bedroom, 4 bathroom house with two 25 kW Vaillant heat-only boilers. The house was extended to 7 bedrooms and 8 bathrooms in total.

50kWTwo 25 kW boilers, before
65kWWhat previous quotes suggested
32kWOne Vaillant ecoTEC plus, range rated to 28.5 kW to cover the extension
24.5kWThe whole house after the loft was insulated, with the boiler range rated down to match

What we found

A full renovation was underway, and the contractor contacted us because previous quotes suggested installing another boiler, to bring the property's capacity up to 65 kW.

One of the two boilers was quite new. Asked how it had been sized, the previous engineer said the old one had broken, so it was replaced with one of the same output.

After a discussion with the client about the building's age and materials, Kirk did a heat loss survey and got 24.5 kW. He redid it and got the same figure, then commissioned an independent survey, which came to 27.5 kW. He isolated one of the boilers, and a couple of weeks later he could show the client the replacement boiler hadn't been needed: the system simply needed re-piping for one boiler.

Before the work, there was no balanced water supply or comfortable heating.

What we did

  • Removed the two 25 kW boilers and fitted one 32 kW Vaillant ecoTEC plus, range rated (its output capped) to 28.5 kW to cover the new extension
  • Advised the client that the old section's loft had minimal insulation. He provided the insulation, and the team added 300 mm across the loft
  • Recalculated the heat loss with the loft insulated: 24.5 kW at -3°C for the whole extended house, and the boiler range rated down to match
  • Replaced the 250 litre cylinder with a 400 litre cylinder with a 3 m² coil
  • Installed underfloor heating in the new section, with radiators upstairs
  • Upgraded the water supply to all outlets
  • Balanced the old section of the property and added 2 new heating zones
  • Priority hot water, with Vaillant sensoCOMFORT thermostats in place of all the third-party thermostats

The result

The extended house ended up back at 24.5 kW, the figure our original survey gave, and around 40 kW below the capacity previous quotes proposed. The client has since reported cost savings and the best hot water ever, despite having more bathrooms.

“This project has been my most challenging and enjoyable to date.”

Kirk Ferguson, Director and Lead Engineer

What the client said

Antony S.Google review · October 2026

Kirk Ferguson of NuRenewables Heating is the most knowledgeable heating engineer/plumber I have ever used and performed an absolutely superb job reworking how my entire heating and hot water system was configured for a large extension. This included installing a new boiler, powertank (to improve the water pressure), hot water cylinder, 3 bathrooms and a kitchen amongst other works.

Kirk is a delight to have in the house, is super tidy, but most of all is an expert in his field and applies a scientific approach to his installations to maximise the efficiency for the homeowner.

Before: two Vaillant boilers side by side in a cupboard, with their pumps and pipework
BeforeThe two 25 kW boilers, 50 kW in total.
Underfloor heating pipe laid through a new extension
Underfloor heatingLaid in the new section of the house.
An underfloor heating manifold with each circuit labelled by room
The manifoldEach circuit labelled with the room it heats.
A Powertank with a booster pump and accumulator, to improve the water pressure
Water supplyUpgraded to all outlets.
A balancing valve fitted on copper heating pipework under the floor
BalancingThe old section of the property, balanced.
A Vaillant sensoCOMFORT thermostat on a wall, showing the room and outdoor temperatures
ControlsVaillant sensoCOMFORT, in place of the third-party thermostats.
A wall-hung system boiler with its copper pipework running down the wall
The Viessmann Vitodens 100-W system boiler

Case study · Hertfordshire

Five heating zones, and priority hot water for five bathrooms

A large property: 6 bedrooms with 5 bathrooms. The property has 5 heating zones, as the client requested.

18.8kWThe design load, at an outside design temperature of -3°C
5Heating zones, as the client requested
300litresUnvented hot water cylinder
5Bathrooms, with priority hot water

A Viessmann Vitodens 100-W system boiler was installed with full weather compensation, for 18.8 kW at an outside design temperature of -3°C. A Viessmann 4 pipe system is used with a 300 litre unvented cylinder, giving priority hot water to the client's five bathrooms and large family while maintaining efficiency.

Heating zone pumps, expansion vessel and copper pipework in a loft plant space
The plant spaceZone pumps, valves and an expansion vessel.
Pumps, valves and copper pipework for the heating zones
Zone pumps and valvesFor the 5 heating zones.
Two underfloor heating manifolds on a plant room wall, each with its own pump
Underfloor heating manifoldsTwo manifolds, each with its own pump.

More projects

Recent projects in London

A few of our recent jobs, with photos from each.

Waterloo, Central London

Renovation of a large property

A full plumbing and heating project.

A Megaflo unvented hot water cylinder with its copper pipework
Copper pipework rising up a wall beside a pump and zone valves
New copper pipework run through an open floor

Richmond upon Thames

Full heating and plumbing installation

A Vaillant boiler in a cupboard beside a Megaflo cylinder
Two new radiators under a bay window with shutters
An underfloor heating manifold and pump with its wiring centre above

North London

Penthouse renovation

An underfloor heating manifold and pump fitted in a framed wall recess
An unvented hot water cylinder with its valves and copper pipework
Insulated pipework run along the floor during a renovation

In progress · London

Beyond heat-loss calculations: understanding how buildings really perform

One of our current London new-build projects features a highly insulated envelope, substantial lower-ground construction and thermal mass, with a calculated design heat loss of approximately 4.2 kW.

The heating design uses predominantly open-loop underfloor heating, carefully balanced circuits, appropriate system water volume and weather-compensated control. After commissioning, OpenEnergyMonitor Level 3 and temporary wireless room-temperature sensors will be used to assess energy performance and room response.

“Good engineering means calculating carefully, selecting appropriately, then measuring and refining for real-world comfort.”

This anonymous case study describes design intent and planned monitoring, not verified post-installation results.

Read Kirk's write-up
4.2kWCalculated design heat loss, approximately
5kWVaillant aroTHERM pro air-source heat pump
≈35°CTarget heating-water flow at winter design conditions
Level 3OpenEnergyMonitor, after commissioning

Our work

Photos from our installs

Heat pumps, boilers, plant rooms, pipework and underfloor heating, each photo from one of our installs.

Heat pump plant room with an unvented hot water cylinder, a second tank, expansion vessel and copper pipework A Vaillant aroTHERM plus heat pump beside a garden hedge Underfloor heating laid on insulation boards across a large floor A plant room with an ONYX hot water cylinder, a second tank and copper pipework Six runs of copper pipe threaded through a timber stud wall in a loft Underfloor heating manifold above the laid pipe circuits An expansion vessel mounted above an unvented hot water cylinder, with insulated pipework Vaillant heat pump controls and internet gateway on a plant room wall

Heat pump plant roomUnvented hot water cylinder, a second tank and expansion vessel, with copper pipework.

Tap a photo, or let it run.

Photo by photo

More from our installs

A finished bedroom with a column radiator under the window
A finished roomA column radiator under the window, in Hertfordshire.
Copper heating pipework run through floor joists
Pipework through the joistsCopper heating pipework run through the floor joists.
Underfloor heating loops laid across a large room with steel columns
Underfloor heating loopsLaid across a large room.
A horizontal hot water cylinder installed in a loft, with copper pipework
Loft cylinderA horizontal hot water cylinder installed in a loft, with its copper pipework.
Two column radiators fitted under windows, with the floor up for the pipework
Radiators going inFitted under the windows, with the floor up for the pipework, in Richmond upon Thames.
Underfloor heating pipe laid in grooved boards
In grooved boardsUnderfloor heating pipe laid in grooved boards, in Richmond upon Thames.
A heating controls wiring centre part-way through wiring
Controls wiring centreA heating controls wiring centre, part-way through wiring.
Parallel runs of new copper pipework, with their bends and clips
Copper pipeworkParallel runs of new copper, with their bends and clips.
Underfloor heating pipe laid across a large open space
Underfloor heatingPipe laid across a large open space.
More case studies are on the way.

Google reviews

What customers say

5.011 Google reviews
Daniele F.Google review · October 2026

Kirk is a master, he helped me to decide which heat pump was suitable for my property,
He take care of everything from the start to the end of the job.
I very impressed of his knowledge. Very recommend.

Pieter D.Google review · October 2026

Kirk is a fantastic heating engineer, who ensures they deliver the right solution for each house, and has gone the extra mile for us to improve the heating and water quality in our house.

Hawa L.Google review · October 2026

Exceptional service every time.
Clean and tidy after. Will recommend this company

Read all 11 reviews

Contact

Want results like these in your home?

Send a few details and we'll get back to you to talk it through.

Get a quote for your home

Please add your name.
Please add your postcode.
Please add a phone number we can call.
Please add a valid email address.

We only use your details to reply to your enquiry. Privacy

Thanks. Your enquiry is with us.

We'll be in touch to talk through your home and what you need.

Get a quote for your home

Step 1 of 3

Three quick steps.

What do you need?
What's the project?
Where should we reply?
Please add your name.
To check we cover your area.Please add your postcode.
So we can call to talk it through.Please add a phone number we can call.
Please add a valid email address.

We only use your details to reply to your enquiry. Privacy

Thanks. Your enquiry is with us.

We'll be in touch to talk through your home and what you need. What happens next:

  1. A discussion to understand your property and what you need.
  2. A property assessment and technical survey.
  3. A detailed quotation, explained.

Prefer to talk? Call 07572 609373

Call us Get my quote